DIN Rail Meters
- 35mm DIN rail mounting
- Compact size for distribution boards
- Single-phase and three-phase metering options
- Prepaid DIN rail option
- Optional stepper register or LCD
- Passive pulse output on metering types
- 50Hz / 60Hz
- Custom wiring available on selected types
Product Overview
-
Wanfang DIN rail meters mount on a 35mm standard rail for distribution boards. The range includes a single-phase meter, a three-phase meter and a prepaid DIN rail meter.
-
Metering types can use a stepper register or an LCD and have a passive pulse output. The prepaid type supports purchase-before-use, load limit, one card or several cards per meter, alarm and automatic disconnect when energy reaches zero.
| Model | Function | Poles | Prepaid | Difference |
|---|---|---|---|---|
| Single-phase DIN rail | Metering | Single-phase | No | About 18mm width; stepper or LCD; passive pulse output |
| Three-phase DIN rail | Metering | Three-phase | No | 3×220/380V or 3×230/400V; stepper or LCD; passive pulse output |
| Prepaid DIN rail | Prepaid | Single-phase | Yes | Purchase before use; load limit; alarm; disconnect at zero energy |
Single-phase DIN Rail Meter

Single-phase DIN rail meter for 35mm rail mounting. Width about 18mm.
- 35mm DIN rail mounting, DIN EN50022
- Width about 18mm, DIN 43880
- Optional stepper 5+1 digits, or LCD 5+2 / 6+1 digits
- Passive pulse output, DIN 43864
- Optional custom neutral wiring, one-in one-out
- Optional LCD in Wh for very small energy totals
| Item | Specification |
|---|---|
| Accuracy | Class 1.0 |
| Rated voltage | 220V / 240V |
| Rated current | 5(25)A, 5(30)A, 5(32)A |
| Starting current | 0.4% Ib |
| Insulation | AC 2kV for 1 min; impulse 6kV |
| Frequency | 50Hz / 60Hz |
| Standards | GB/T17215-2002, IEC62053-21 |
Three-phase DIN Rail Meter

Three-phase DIN rail meter for 35mm rail mounting.
- 35mm DIN rail mounting, DIN EN50022
- Optional stepper 5+1 digits, or LCD 5+2 / 6+1 digits
- Passive pulse output, DIN 43864
- Optional custom neutral wiring, one-in one-out
- Optional LCD in Wh for very small energy totals
| Item | Specification |
|---|---|
| Accuracy | Class 1.0 |
| Rated voltage | 3×220/380V, 3×230/400V |
| Rated current | 3×5(25)A, 3×5(30)A, 3×5(100)A |
| Starting current | 0.4% Ib |
| Insulation | AC 2kV for 1 min; impulse 6kV |
Prepaid DIN Rail Meter

Single-phase prepaid meter for 35mm DIN rail. Purchase energy before use.
- 35mm DIN rail mounting
- Computer-managed prepaid use
- Load-limit control available
- One meter with one card, or one meter with several cards
- Lost card does not cut power; a replacement card can be issued
- Card transfers data in both directions
- Alarm for low energy and overload
- Disconnect when energy is zero
- Overload disconnect; power returns after about 3 minutes, or at once after a card action
- Credit overdraft can be set by the utility, up to 99 kWh
- Maximum stored energy 99999.99 kWh
| Item | Specification |
|---|---|
| Accuracy | Class 1.0 / Class 2.0 |
| Rated voltage | 220V |
| Rated current | 5(30)A, 15(50)A, 15(60)A |
| Starting current | 0.4% Ib |
| Frequency | 50Hz / 60Hz |
| Working temperature | -20℃ to +55℃ |
| Limit temperature | -25℃ to +60℃ |
| Relative humidity | ≤85% |
| Standards | GB/T17215-2002, GB/T18460.3-2001, DL/T645-1997 |
Ready to get a quote?