Three Phase Meters

  • Three-phase active energy metering
  • Long-term operation without calibration
  • Dedicated IC and SMT assembly
  • IC card prepaid options
  • Remaining-energy alarm
  • Overload disconnect with event record
  • RS485 / infrared options on selected models
  • Irrigation and multi-tariff options

Product Overview

  • Wanfang three-phase meters cover postpaid metering, IC card prepaid meters, a three-phase three-wire irrigation meter, a multi-tariff meter and a multi-function meter.

  • Prepaid models use one meter with one card. The meter can alarm when remaining energy is low, disconnect on overload and record overload times. A summary card can read back the user number and accumulated energy.

  • The irrigation meter supports more than one card per meter and two card-control modes for pump use.

Model Function Display Prepaid Difference
Electronic kWh Metering No Keeps working if one or two phases are lost; optional 485 and test pulse
DTSY428 Digital Prepaid Digital Yes One card per meter; remaining-energy alarm; overload record; summary card
DTSY428 Dual display Prepaid Dual digital Yes Same functions as digital type; dual display
Prepaid LCD Prepaid LCD Yes Shows total kWh, remaining energy and meter number
DSSY428 Irrigation Irrigation prepaid Yes Three-phase three-wire; multi-meter multi-card; two card-control modes
DTSF428 TOU TOU 4 tariffs, 8 periods; forward/reverse active energy; max demand; IR and RS485
DTSD Multi-function Multi-function Active/reactive energy; demand; voltage-loss record; monthly settlement
Electronic kWh Meter

Three-phase active energy meter. Postpaid metering. Long-term operation without calibration.

  • Dedicated IC and SMT assembly; simple peripheral circuit
  • Keeps working if any one or two phases are lost
  • Optional remote 485 and energy test pulse output
  • High in-service accuracy, including on harmonic loads
Item Specification
Accuracy Class 1.0 / Class 2.0
Meter constant 1600imp/kWh
Current 1.5(6)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
Dimensions 278mm × 172mm × 74mm
Operating temperature -20℃ to +50℃
Relative humidity ≤85%
Power consumption Voltage circuit <1W / 5VA
DTSY428 Prepaid Meter, Digital

Three-phase four-wire IC card prepaid meter with digital display.

  • Active energy metering; long-term operation without calibration
  • IC card prepaid; one meter, one card
  • Remaining-energy alarm
  • Overload disconnect and record of overload times
  • Records the user’s maximum load
  • Summary card reads back user number and accumulated energy
Item Specification
Accuracy Class 1.0 / Class 2.0
Current 1.5(6)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
Alarm output AC220V / 0.5A
Operating temperature -20℃ to +50℃
Relative humidity ≤85%
Power consumption Voltage circuit <1W / 5VA
Weight About 3.25kg
Standards GB/T17215.321-2008, GB/T18460.3-2001
DTSY428 Prepaid Meter, Dual Display

Same functions as the digital prepaid meter. Dual digital display.

  • Active energy metering; long-term operation without calibration
  • IC card prepaid; one meter, one card
  • Remaining-energy alarm
  • Overload disconnect and record of overload times
  • Records the user’s maximum load
  • Summary card reads back user number and accumulated energy
Item Specification
Accuracy Class 1.0 / Class 2.0
Current 1.5(6)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
Alarm output AC220V / 0.5A
Operating temperature -20℃ to +50℃
Relative humidity ≤85%
Power consumption Voltage circuit <1W / 5VA
Weight About 3.25kg
Standards GB/T17215.321-2008, GB/T18460.3-2001
Prepaid Meter, LCD

Three-phase four-wire IC card prepaid meter with LCD. Shows total consumption, remaining energy and meter number.

  • Active energy metering; long-term operation without calibration
  • IC card prepaid; one meter, one card
  • Remaining-energy alarm
  • Overload disconnect and record of overload times
  • Shows total consumption, remaining energy and meter number
  • Records the user’s maximum load
  • Summary card reads back user number and accumulated energy
Item Specification
Accuracy Class 1.0 / Class 2.0
Voltage 3×220V/380V
Current 1.5(6)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
Meter constant 1.5(6)A: 1600imp/kWh; 5(20)A: 800imp/kWh; 40A and above: 400imp/kWh
Alarm output AC220V / 0.5A
Operating temperature -20℃ to +50℃
Relative humidity ≤85%
Power consumption Voltage circuit <1W / 5VA
Weight About 3.25kg
Standards GB/T17215.321-2008, GB/T18460.3-2001
DSSY428 Irrigation Meter

Three-phase three-wire prepaid meter for irrigation pumps. Multi-meter, multi-card.

  • Active energy metering; long-term operation without calibration
  • IC card prepaid; multi-meter, multi-card
  • Two modes: card-in for power / card-out to disconnect; or card-in for power, card-in again to take power off
Item Specification
Accuracy Class 1.0 / Class 2.0
Current 1.5(6)A, 5(20)A, 10(40)A, 15(60)A, 20(80)A, 30(100)A
Meter constant 3×1.5(6)A: 1600imp/kWh; 10(40)A, 15(60)A, 20(80)A, 30(100)A: 400imp/kWh
Normal working voltage 0.8 to 1.15 × Un
Limit working voltage 0.7 to 1.20 × Un
Power consumption ≤2W and 10VA (single phase)
Normal temperature -25℃ to +55℃
Limit temperature -40℃ to +60℃
Annual average humidity ≤75%
DTSF428 Multi-Tariff Meter

Three-phase four-wire multi-tariff meter. Four tariffs and eight time periods.

  • Dedicated IC and SMT assembly
  • EMC design
  • Backup battery for operation after power outage
  • Forward and reverse active energy
  • Maximum demand
  • 4 tariffs and 8 time periods
  • Infrared and RS485 communication
Item Specification
Accuracy Class 1.0 / Class 2.0
Voltage 3×220/380V
Frequency 50Hz
Current 3×1.5(6)A, 3×5(20)A, 3×10(40)A, 3×15(60)A, 3×20(80)A, 3×30(100)A
Meter constant 1600 / 800 / 400 imp/kWh
Power consumption <2W
Weight About 1kg
DTSD Multi-Function Meter

Three-phase four-wire multi-function meter for active and reactive energy, tariffs, demand and voltage-loss records.

  • Active and reactive energy with separate pulse outputs
  • 4 tariffs and 8 periods; stores energy by tariff
  • Maximum demand by sliding window; stored by month
  • Voltage-loss records with start and restore time
  • Alarm and trip for remaining credit, allowed load and voltage loss
  • Automatic settlement on a set day; about 3 months of billing data
  • Reading during power outage
  • Works if any one phase is present
  • Data kept for at least 10 years
Item Specification
Active accuracy Class 0.5 / Class 1.0
Reactive accuracy Class 2.0
Current 1.5(6)A, 3(6)A, 10(40)A, 30(100)A
Data retention ≥10 years after power loss
Operating temperature -30℃ to +45℃
Relative humidity ≤85%
Clock error ≤0.5 s/day